    Q1. What's the MOQ? A. 2pcs Q2. what's the payment term? A. We accept TT, 30% deposit and 70% balance before shipment, Western Union, Paypal payment Q3. What's the sample time and lead time for mass productions? A. Normally, sample time is about 3-7 days after receiving your details. Lead time for mass productions (500pcs) is about 30 days. Q4. What is the standard of package? A. We usually use carton box, flight case, carton with wooden frame is also ok if required. Q5. How about the transport?...

    2018-Mar-17
  • Company FAQ

    Q1.You are factory or trading company? A.We are a professional stage lighting company that is mainly engaged in the product research and development, design,production, sale and service with our own factory. Q2. What are your main products lines? A.We specialise in moving head beam, spot, wash, battery lights and so on. Q3. How many kind of products do you have? A. over 100, move products are under developing Q4. What kind of certificate you have? A.We have ROHS, CE, EMC, as well as national pat...

    2018-Mar-17

The Solution of Moving Head Light Malfunctions

2018-02-26

It is common to find malfunctions of the moving head lights on the stage including the light bulbs are not controlled, the light bulbs are off or suddenly go out, etc. Sudden failures often cause great embarrassment and inconvenience to the stage lighting performance.

Common fault 1: computer moving head light bulb are off.
1. Turn on the tail of the lamp body to check if the lamp is white or black. If there are any of the above two phenomena, try replacing the lamp and try again.
2. Open the shells, install a trigger on the lamp post, check whether the trigger connection is black, if there is to replace the trigger.


Common fault 2: the computer moving head lamp is on and off.
1. Check if the light bulb is white, black or soaring. Replace the light bulb when these conditions appear, to avoid damage to the stage lighting equipment.
2. Check if the fan near both sides of the bulb is working properly. If there is something bad, replace the fan immediately.
3. Please open the two shells. There is a white temperature control in the layer of the pattern sheet and the color film, to see if it is burned out (if it is broken, it will not disappear);
4. Turn on the two housings of the lamp body. The heat dissipation window on the rear part of the lamp bulb will block the air inlet and outlet for a long time. If the heat dissipation window is covered with dust, please clean it immediately. The cleaning time is better cleaning once every month.)

Request a Free Quote

If you have questions or suggestions, please leave us a message

With several years of experience, we will light culture the new idea and practice together and are widely used in stage lighting design in. We have over several years of professional experience in stage lighting technicians and our product obtained many national patents at present.